Find a Store Find a Pro Contact Us My Folders
North America
  • US
  • Canada
  • Mexico
South America
  • Latin America
  • Brazil
Africa
  • Africa
  • Middle East
Europe
  • Europe
  • Germany
  • UK
Asia
  • China
  • Hong Kong
  • India
  • Indonesia
  • Malaysia
  • Mongolia
  • Philippines
  • Singapore
  • South Korea
  • Taiwan
  • Thailand
  • Vietnam
Oceania
  • Australia
  • New Zealand
Logo
hamburger menu
  • Find a Store
  • Find a Pro
  • Contact Us
  • My Folders
  • KOHLER Worldwide
    • US
    • Canada
    • Mexico
    • Latin America
    • Brazil
    • Africa
    • Middle East
    • Europe
    • Germany
    • UK
    • China
    • Hong Kong
    • India
    • Indonesia
    • Malaysia
    • Mongolia
    • Philippines
    • Singapore
    • South Korea
    • Taiwan
    • Thailand
    • Vietnam
    • Australia
    • New Zealand

Topics

  • Home

  • {[{category.name}]}

    • {[{section.name}]}
  1. KOHLER
  2. Showering/Valves
  3. Installation

K-11748 Valve - Additional Outlets

Affected SKUs

K-11748-* Rite-Temp® Pressure Balancing Valve with Diverter


If K-11748 Needs Additional Outlets

IMPORTANT! Do not install a valve with a shut-off after the shower port, as this may result in cross-flow of the water.

NOTE: If you want to use a showerhead and handshower at the same time, the K-11748 valve should not be used. There will not be sufficient water flow. We recommend you install a K-304 valve and follow the steps in the "K-304 Valve - Adding a Transfer/Diverter Valve" document. A diverter bath spout is required for this installation.

NOTE: If the transfer or diverter valve is only being used as a 2-way valve, a 2-way conversion must be completed following the instructions provided.

  • Install the K-11748 following the instructions provided with the valve.
  • If needed, install a K-728 transfer valve or K-737 diverter valve in-line with the top outlet following the instructions provided with the valve.
  • If two outlets will be used, convert the valve to a 2-way valve.
  • If additional ports are needed for your shower configuration when using a K-11748 valve, an additional valve can be added above the top port at the location shown.

NOTE: For more information on the K-728 transfer valve or K-737 diverter valve, including installation instructions, go to the product page at www.us.kohler.com.

Click Here For Maintenance And Service Parts

1243674-10-A  ©Kohler Co.

  • Facebook
  • Twitter
  • LinkedIn
Was this article helpful?
6 out of 18 found this helpful
Return to top

Related articles

  • K-2971 Rite-Temp Valve Installed with a Tub Spout Only