Remove the Existing Centerguide
- Lift the threshold seal to access the screw.
- Loosen the screw with a 5/32" hex wrench.
- Slide the centerguide down the threshold until it clears the door panels.
- Lift the centerguide from the threshold lip.
Install the New Centerguide
IMPORTANT! The centerguide must be fully seated behind the threshold lip as shown.
- Slide both door panels to one end of the shower.
- Thread the screw partially into the centerguide hole. Ensure the end of the screw does not protrude from the bottom of the centerguide.
- Measure and mark the centerline of the threshold on the outside of the shower base/bath ledge.
- Rotate the centerguide into place in the threshold groove as shown.
- Slide the centerguide down the threshold until the screw aligns with the centerline mark.
- Slide the door panels into the centerguide channels.
- Lift the threshold seal to access the screw.
- Handtighten the screw with a 5/32″ hex wrench, then tighten an additional one half turn.
Click Here For Maintenance And Service Parts
1201264-10-B ©Kohler Co.